The Lantex® 100 is the only NFPA 1999 certified single-use garment that provides you protection for fentanyl reponse situations at an economical price. It has a breathable barrier fabric for enchanced comfort and a tactical garment design. This suit also provides proven blood and viral protection passing both the ASTM F16750 blood penetration and the ASTM F1671 blood/viral penetration tests. The tatical style is designed for law enforcement response and has a unique rear-entry design that allows safer doffing helping to prevent cross-contamination. 
Color:
Black
Sizing:
SM-4XL
Case Quantity:
6 per Case
Seam Style:
Heat Sealed/Taped Seams
Model:
L1H459-99
| Performance Requirement | Test Method | Requirement | Result | 
| Garment | |||
| Liquidtight Integrity  (Test One)  | 
ASTM F1359 (Section 8.2) | No liquid penetration | PASS | 
| Liquidtight Integrity  (Test One)  | 
ASTM F1154, mod. (Section 8.40) | Complete tasks in ≤ 20 min with garment closure remaining engaged Test subject properly identifies 3 out of 4 numbers on NFPA 704 placard at each angle Visual acuity ≥ 20/35 Protective flap remains closed over closure system No liquid penetration following exercises  | 
PASS | 
| Garment Material | |||
| Biopenetration  (Test One)  | 
ASTM F1671  (Section 8.3)  | 
No penetration of Phi-X174 bacteriophage | PASS | 
| Burst Strength | ASTM D3787  (Section 8.5)  | 
≥ 66 N (14.9 lbf) | 125 N | 
| Puncture Propagation Tear Resistance | ASTM 2582  (Section 8.6)  | 
≥ 12 N (2.7 lbf) | 30 N (MD) 68 N (CD)  | 
| Flammability | ASTM D1230  (Section 8.35)  | 
Flame spread ≥ 3.5 sec | 13.3 sec (MD)  8.3 sec (CD)  | 
| Moisture Vapor Transmission Rate | ASTM E96, Proc. B, mod.  (Section 8.28)  | 
≥ 650 g/m2/24 hr | 4659 g/m2 / 24hrs | 
| Seams | |||
| Biopenetration  (Test One)  | 
ASTM F1671  (Section 8.3)  | 
No penetration of Phi-X174 bacteriophage | PASS | 
| Seam Breaking Strength | ASTM D1683  (Section 8.8)  | 
≥ 50 N (11.2 lbf) | 217 N (body)  142 N (flap)  |